The control, by the way, has been installed and is running in the meantime. However, there are a few changes: All cables were routed to the meter cabinet, and the control was mounted there on free DIN rails. I also replaced the terminals with three-level terminals due to space constraints.
Of course, I didn’t take a photo again.
But I can show the programming in #FBD (Function Block Diagram).
#SiemensLOGO #PLC #ProgrammableLogicController #SPS #SpeicherProgrammierbareSteuerung
-
I have many LOGO versions but no 0BA4. 🤔
Anyway, I have now taken an OBA3 24V AC/DC and plugged the old control unit into it. As the controller works with 24V like the 230V version, this is not a problem.
It also starts and that means the controller works. Wonderful! In the next step I can read out the program 🙂
(Addding some hashtags):
#Siemens #SiemensLOGO #PLC #ProgrammableLogicController #SPS #SpeicherProgrammierbareSteuerung #Troubleshooting #Repair -
Today I found the time to finish the #wiring 🫠.
I used some smaller #contactors that I found in my stash. I then simply applied voltage to it as a test. The first contactor also switched directly every second because a program was still active on the #controller.
Now I just need to program the controller, which won't be a big deal.
🧵1/6
#SiemensLOGO #PLC #ProgrammableLogicController #SPS #Kleinsteuerung #RCD #TerminalBlocks #wire #wires #Weidmüller #ABB #Siemens
-
It's getting a bit Lego-heavy here, but I can't find anything else at the moment.
At least I've #integrated one of my #toys. 😁
I used a #SiemensLOGO 0BA5 with #extension to #automate a #Lego #LevelCrossing (4532). It #controls the station #lighting, the #TrafficLights and the level crossing #barrier.
The #controller runs on 24 #volts, the lighting and the #motor are #regulated down to 3 volts via a #StepDown #module.
#ProgrammableLogicController #PLC #SPS #Siemens #LOGO #ProgrammableThings
-
It's getting a bit Lego-heavy here, but I can't find anything else at the moment.
At least I've #integrated one of my #toys. 😁
I used a #SiemensLOGO 0BA5 with #extension to #automate a #Lego #LevelCrossing (4532). It #controls the station #lighting, the #TrafficLights and the level crossing #barrier.
The #controller runs on 24 #volts, the lighting and the #motor are #regulated down to 3 volts via a #StepDown #module.
#ProgrammableLogicController #PLC #SPS #Siemens #LOGO #ProgrammableThings