  1. #safety101
    Found this photo of the 2G ICE ammonia reformate genset test at Amogy's #amogyinc labs.

    1) Glad to see a safety shower to rinse off any ammonia accidents
    2) Don't see any double-block-and-bleed valve setup (standard with fuel installations).
    3) Don't see any high-mounted ammonia or hydrogen sensors in either test bay (both gases are lighter than air.
    4) Don't see any flame detectors in either test bay.

  2. #safety101 #chemistry101 #RTM
    Two dead & 19 injured after a volatile reaction at a silver recovery plant in WV 22Apr2026.

    Nitric acid mixed with "M2000A" evolved toxic hydrogen sulfide gas.

    FWIW: the possible double displacement reaction:

    2 Na₂S + 4 HNO₃ → 2 H₂S + 4 NaNO₃

  3. #Hydrogen101 #Safety101 #H2Safety

    RE: Clyde Hydrogen demo of integrated decoupled electrolyzer prototype.

    ⬇️Claim "Safety-no possibility of #hydrogen and #oxygen mixing"

    UNTRUE: flow sheet shows O2 could travel with liquid mediator to catalytic hydrogen generator.
    H2 + O2 = BAD!

  4. #Hydrogen101 #Safety101 #H2Safety

    RE: Clyde Hydrogen demo of integrated decoupled electrolyzer prototype.

    ⬇️Claim "Safety-no possibility of #hydrogen and #oxygen mixing"

    UNTRUE: flow sheet shows O2 could travel with liquid mediator to catalytic hydrogen generator.
    H2 + O2 = BAD!

  5. RE: mastodon.mit.edu/@keithdpatch/

    #Safety101 #H2Safety
    How can a French factory reopen after an explosion kills 2 workers, without finding the cause of the blast?

    Silicone plants often use hydrogen; unsafe #hydrogen levels can explode; 1 died in this plant in 2016 & a 2nd safety incident in 2025!!

    It makes me wonder if this plant is under new US "safety" regulations, or still follows EU requirements...[insert smirk emoji here!]

    bit.ly/4pl1K5C #H2 #safety

  6. #Ammonia101 #Safety101
    Oh sure, we need to convert as much green hydrogen to green ammonia as possible...says nobody aware of the severe health hazards of ammonia!

    Hundreds got evacuated in Weatherford, Oklahoma; 34 hospitalized, several in critical condition, but nobody died!
    #NH3 #ammonia #OK
    tiktok.com/@abcnews/video/7572

  7. #Safety101
    HD Hyundai HHI now has ammonia-fueled 2.2MWe & 5.4MWe dual-fuel DI ICE engines.↙️

    Hyundai claims a Selective Catalytic Reduction #SCR system will eliminate toxic ammonia & nitrogen oxide emissions.↘️

    NOTE: SCR systems are ineffective on cold starts!
    -They need high temperatures (around 200C - 250C) to work, leading to high temporary ammonia & NOx emissions.
    -The Immediately Dangerous to Life or Health #IDLH concentration for ammonia is 300 parts per million (ppm)! #woops

  8. #Safety101
    HD Hyundai HHI now has ammonia-fueled 2.2MWe & 5.4MWe dual-fuel DI ICE engines.↙️

    Hyundai claims a Selective Catalytic Reduction #SCR system will eliminate toxic ammonia & nitrogen oxide emissions.↘️

    NOTE: SCR systems are ineffective on cold starts!
    -They need high temperatures (around 200C - 250C) to work, leading to high temporary ammonia & NOx emissions.
    -The Immediately Dangerous to Life or Health #IDLH concentration for ammonia is 300 parts per million (ppm)! #woops

  9. #Safety101 #HydrogenSafety #Hydrogen101
    Korea Minister of Employment and Labor Kim Young-hoon issued an emergency directive on the 17th (the same day as the most-recent accident) regarding the #H2 explosion.
    It is actually the 2nd #hydrogen pipeline accident this year!
    Korea needs to establish a culture of hydrogen safety ASAP!

  10. #Safety101 #HydrogenSafety #Hydrogen101
    🔥 Fire at hydrogen production unit in SK Energy Ulsan, Korea refinery injures 5. ↙️
    ↘️ Likely root cause: failure to follow standard operating procedure #SOP & purge residual hydrogen gas from pipeline before opening the line. Released gas cloud exploded.
    #hydrogen #H2

  11. #safety101 #hydrogen101
    NOW: Chinese hydrogen electrolyzers from 3 vendors are still not operating due to "too high" grid power price.↙️🤥

    11Dec2023: It was "…due to…missing safety features in the system design and lower-than-promised efficiencies."↘️
    HT HydrogenInsight #GreenHydrogen #H2 #safety